TM 5-3805-296-23-1
0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Test Main Relay Supply
0562-02 Caterpillar
Voltage at Circuit Breaker Panel.
Monitoring System Incorrect
1. Turn ignition switch and battery
Signal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove fuse F40 from circuit
breaker panel
(TM 5-3805-296-10).
3. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
Voltage 18 to 26 V Proceed to Test
Step 7.
(WP 0540), test for voltage
Voltage Less Than 18 V Replace
between fuse F40 right terminal
(Figure 3) and ground.
fuse panel wiring harness (WP 0515).
Proceed to Test Step 13.
Figure 3. Testing Voltage to Fuse F40.
0059