Table 1. 0562 Monitoring System Diagnostic Codes.
Figure 2. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  818    819    820    821    822  823  824    825    826    827    828  
img
.
TM 5-3805-296-23-1
0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test Voltage of Battery
0562-02 Caterpillar
Circuit at Tractor Operator Monitor.
Monitoring System Incorrect
1. Turn ignition switch and battery
Signal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove six bolts
(Figure 1, Item 1), washers
(Figure 1, Item 2), and instrument
panel cover (Figure 1, Item 3) from
ROPS (Figure 1, Item 4).
Figure 1. Instrument Panel Cover and Retaining Hardware.
0059