• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Instrument Panel Cover and Retaining Hardware.
Table 1. 0562 Monitoring System Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  819    820    821    822    823  824  825    826    827    828    829  
img
. . . .
TM 5-3805-296-23-1
0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove two bolts
0562-02 Caterpillar
(Figure 2, Item 1) and left vent
Monitoring System Incorrect
(Figure 2, Item 2) from instrument
Signal Continued
panel (Figure 2, Item 3).
4. Remove two bolts
(Figure 2, Item 6) and right vent
(Figure 2, Item 7) from instrument
panel (Figure 2, Item 3).
5. Remove six bolts (Figure 2, Item 4)
from instrument panel
(Figure 2, Item 3) and ROPS
(Figure 2, Item 5). Position
instrument panel to
access connector P-C18
(WP 0012, Figure 269).
Figure 2. Instrument Panel and Retaining Hardware.
0059
6. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor.
7. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
8. Using digital multimeter
Voltage 18 to 26 V Proceed to Test
(WP 0540), test for voltage
Step 2.
between connector P-C18
Voltage Less Than 18 V Proceed to
terminal 1 (WP 0012, Figure 269)
Test Step 6.
and ground.
0059-4