0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
5. Connect jumper wire between
0562-02 Caterpillar
terminal 7 and terminal 8
Monitoring System Incorrect
of connector W-C12
Signal Continued
(WP 0540), measure resistance
Proceed to Test Step 5.
between connector W-C7
terminal 53 and terminal 54
Replace main cab wiring harness
(WP 0505).
Proceed to Test Step 13.
Test Step 5. Verify if Code is Still
Active.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. Connect MSD, check for active
562-2 Caterpillar Monitoring System
diagnostic code 0562-02
Incorrect Signal Becomes Inactive
Caterpillar Monitoring System
Troubleshooting complete. Proceed to
step 4.
562-2 Caterpillar Monitoring System
Incorrect Signal Remains Active
Replace tractor operator monitor
(WP 0506).
Proceed to Test Step 13.
4. Install instrument panel
(Figure 2, Item 3) with six bolts
(Figure 2, Item 4) on ROPS
(Figure 2, Item 5).
5. Install right vent (Figure 2, Item 7)
with two bolts (Figure 2, Item 6)
on instrument panel
(Figure 2, Item 3).
6. Install left vent (Figure 2, Item 2)
with two bolts (Figure 2, Item 1) on
instrument panel
(Figure 2, Item 3).
7. Install instrument panel cover
(Figure 1, Item 3) with six washers
(Figure 1, Item 2) and bolts
(Figure 1, Item 1) on ROPS
(Figure 1, Item 4).
8. If removed, install lower and upper
plenum on ROPS (WP 0504).
0059-6