TM 5-3805-296-23-1
0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
562-2 Caterpillar Monitoring System
3. At MSD, check for active
0562-02 Caterpillar
Incorrect Signal Becomes Inactive
diagnostic code 562-2 Caterpillar
Monitoring System Incorrect
Troubleshooting complete. Proceed to
Monitoring System Incorrect
Signal Continued
step 4.
Signal (WP 0008).
562-2 Caterpillar Monitoring System
Incorrect Signal Remains Active
Proceed to Test Step 11.
4. Install step (Figure 4, Item 3), six
washers (Figure 4, Item 2), and
bolts (Figure 4, Item 1) on cab
(Figure 4, Item 4).
5. Install instrument panel
(Figure 5, Item 3) with six bolts
(Figure 5, Item 4) on ROPS
(Figure 5, Item 5).
6. Install right vent (Figure 5, Item 7)
with two bolts (Figure 5, Item 6)
on instrument panel
(Figure 5, Item 3).
7. Install left vent (Figure 5, Item 2)
with two bolts (Figure 5, Item 1) on
instrument panel
(Figure 5, Item 3).
Figure 5. Instrument Panel and Retaining Hardware.