• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 2417 Start Aid Diagnostic Codes Continued.
Table 1. 2417 Start Aid Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  707    708    709    710    711  712  713    714    715    716    717  
img
. .
TM 5-3805-296-23-1
0041
Table 1. 2417 Start Aid Diagnostic Codes Continued.
041
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 10. Verify Malfunction is
2417-05 Ether Injection
Resolved.
Control Solenoid Current
1. Ensure all harness connectors are
Below Normal Continued
connected.
2. Turn battery disconnect switch to
ON position and start engine
(TM 5-3805-296-10).
3. At MSD, check for active
2417-5 Ether Injection Control
diagnostic codes (WP 0008).
Solenoid Current Below Normal
Becomes Inactive Proceed to step 4.
2417-5 Ether Injection Control
Solenoid Current Below Normal
Remains Active Repeat
troubleshooting from the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0041
6. If lowered, install left frame access
plate (WP 0376).
7. Troubleshooting complete.