Figure 4. Cab Step.
Figure 6. Instrument Panel Cover and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  666    667    668    669    670  671  672    673    674    675    676  
img
. .
TM 5-3805-296-23-1
0037
Table 1. 0562 Module Communication Diagnostic Codes Continued.
037
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
562-9 Caterpillar Monitoring System
3. At MSD, check for active
0562-09 Caterpillar
Abnormal Update Rate Becomes
diagnostic code 562-9 Caterpillar
Monitoring System
Inactive Troubleshooting complete.
Monitoring System Abnormal
Abnormal Update Rate
Proceed to step 4.
Update Rate (WP 0008).
Continued
562-9 Caterpillar Monitoring System
Abnormal Update Rate Remains
Active Proceed to Test Step 15.
4. Install step (Figure 4, Item 3), six
washers (Figure 4, Item 2), and
bolts (Figure 4, Item 1) on cab
(Figure 4, Item 4).
5. Install instrument panel
(Figure 5, Item 3) with six bolts
(Figure 5, Item 4) on ROPS
(Figure 5, Item 5).
6. Install right vent (Figure 5, Item 7)
with two bolts (Figure 5, Item 6)
on instrument panel
(Figure 5, Item 3).
7. Install left vent (Figure 5, Item 2)
with two bolts (Figure 5, Item 1)
on instrument panel
(Figure 5, Item 3).
Figure 5. Instrument Panel and Retaining Hardware.