TM 5-3805-296-23-1
0037
Table 1. 0562 Module Communication Diagnostic Codes Continued.
037
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0562-09 Caterpillar
8. Install left vent (Figure 5, Item 2)
Monitoring System
with two bolts (Figure 5, Item 1)
Abnormal Update Rate
on instrument panel
(Figure 5, Item 3).
Continued
9. Install instrument panel cover
(Figure 6, Item 3) with six washers
(Figure 6, Item 2) and bolts
(Figure 6, Item 1) on ROPS
(Figure 6, Item 4).
10. If removed, install lower and upper
plenum on ROPS (WP 0504).
11. Troubleshooting complete.
NOTE
0562-12 Wrong Response
From Cat Monitoring System
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Tractor Operator Monitor Software Incorrect or Requires Updating.
Engine ECM Software Incorrect or Requires Updating.
POSSIBLE CAUSE
Tractor Operator Monitor Programming.
Engine ECM Programming.
Test Step 1. Program Tractor
Operator Monitor.
Refer to ECM Programming
Program tractor operator monitor with
Proceed to Test Step 2.
Test Step 2. Program Engine ECM.
Refer to ECM Programming
Program engine ECM with correct soft-
correct operation of machine
(TM 5-3805-296-10). Troubleshooting
complete.
END OF WORK PACKAGE