TM 5-3805-296-23-5
0322
INSTALLATION CONTINUED
NOTE
Install fittings as noted during removal.
6. Install new O-ring (Figure 9, Item 9) and fitting (Figure 9, Item 7) on implement pilot solenoid pressure reducing
valve assembly (Figure 9, Item 6).
7. Install new O-ring (Figure 9, Item 8) on fitting (Figure 9, Item 7).
8. Install new O-ring (Figure 9, Item 3) and fitting (Figure 9, Item 4) on implement pilot solenoid pressure reducing
valve assembly (Figure 9, Item 6).
9. Install new O-ring (Figure 9, Item 5) on fitting (Figure 9, Item 4).
10. Install new O-ring (Figure 9, Item 2) and fitting (Figure 9, Item 1) on implement pilot solenoid pressure reducing
valve assembly (Figure 9, Item 6).
11. Install new O-ring (Figure 9, Item 10) on fitting (Figure 9, Item 1).
Figure 9. Implement Pilot Solenoid Pressure Reducing Valve Assembly.
0322