TM 5-3805-296-23-5
0322
REMOVAL CONTINUED
NOTE
If installing new implement pilot solenoid pressure reducing valve body, perform steps 21
and 22 on original implement pilot solenoid pressure reducing valve body.
21. Install original test port (Figure 6, Item 2) on original implement pilot solenoid pressure reducing valve
(Figure 6, Item 3).
22. Install original dust cover (Figure 6, Item 1) on original implement pilot solenoid pressure reducing valve
(Figure 6, Item 3).
Figure 6. Original Implement Pilot Solenoid Pressure Reducing Valve Body.
0322
END OF TASK
CLEANING AND INSPECTION
000322
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK