NOTE
Complete steps 1 and 2 if new implement pilot solenoid pressure reducing valve is being
installed.
1. Remove dust cover (Figure 7, Item 1) from test port (Figure 7, Item 2).
2. Remove test port (Figure 6, Item 2) and O-ring (Figure 7, Item 3) from implement pilot solenoid pressure
reducing valve (Figure 7, Item 4). Discard O-ring.
Figure 7. Test Port.