TM 5-3805-296-23-5
0322
REMOVAL CONTINUED
NOTE
Note location of tiedown strap to aid in installation.
Tag and mark wiring harness connector to aid in installation.
7. Remove tiedown strap (Figure 2, Item 4) from ladder clip (Figure 2, Item 3). Discard tiedown strap.
8. Disconnect wiring harness connector (Figure 2, Item 5) from implement pilot solenoid (Figure 2, Item 1).
9. Remove implement pilot solenoid pressure reducing valve assembly (Figure 2, Item 2) from machine.
Figure 2. Solenoid Connection.
0322