Figure 1. Instrument Panel Cover and Retaining Hardware.
Table 1. 0819 Display Data Link Diagnostic Code Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  483    484    485    486    487  488  489    490    491    492    493  
img
.
TM 5-3805-296-23-2
0099
Table 1. 0819 Display Data Link Diagnostic Code Continued.
099
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove two bolts
0819-02 Display Data Link
(Figure 2, Item 1) and left vent
Erratic, Intermittent, or
(Figure 2, Item 2) from instrument
Incorrect Continued
panel (Figure 2, Item 3).
4. Remove two bolts
(Figure 2, Item 6) and right vent
(Figure 2, Item 7) from instrument
panel (Figure 2, Item 3).
NOTE
DO NOT disconnect connector P-C1 (WP 0012, Figure 253) from W-C7
(WP 0012, Figure 252).
5. Remove six bolts (Figure 2, Item 4)
from instrument panel
(Figure 2, Item 3) and ROPS
(Figure 2, Item 5). Position
instrument panel to access
connector P-C19
(WP 0012, Figure 270).