TM 5-3805-296-23-2
0098
Table 1. 0324 Action Lamp Diagnostic Codes Continued.
098
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Shorted Dash
0324-06 Warning Lamp
Wiring Harness.
Short to Ground
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove apron float LED from
connector P-C31 and install LED
on connector P-C22. Connect
connector P-C22 on instrument
panel (WP 0506) (Figure 9).
3. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor connector.
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C18
Proceed to Test Step 3.
terminal 13 (WP 0012, Figure 253)
No Continuity Proceed to step 9.
and all other terminals in
connector P-C18 (WP 0012,
Figure 253).
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C18
Proceed to Test Step 3.
terminal 13 (WP 0012, Figure 253)
No Continuity Replace tractor
and ground.
operator monitor (WP 0506).
Proceed to Test Step 3.
Test Step 3. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
325-6 Warning Lamp Short To
diagnostic codes (WP 0008).
Ground Becomes Inactive Proceed
to step 4.
325-6 Warning Lamp Short To
Ground Remains Active Repeat
troubleshooting from the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install instrument panel
(Figure 9, Item 3) with six bolts
(Figure 9, Item 4) on ROPS
(Figure 9, Item 5).
0098-14