Table 1. 0324 Action Lamp Diagnostic Codes Continued.
098
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
6. If removed, install right vent
0324-05 Warning Lamp
(Figure 6, Item 7) with two bolts
Open/Short to Ground
(Figure 6, Item 6) on instrument
Continued
panel (Figure 6, Item 3).
7. If removed, install left vent
(Figure 6, Item 2) with two bolts
(Figure 6, Item 1) on instrument
panel (Figure 6, Item 3)
8. If removed, install instrument panel
cover (Figure 6, Item 3) with six
washers (Figure 6, Item 2) and
bolts (Figure 6, Item 1) on ROPS
(Figure 6, Item 4).
9. Troubleshooting complete.
NOTE
0324-06 Warning Lamp
Short to Ground
Always inspect harness connectors that are involved in the circuit. Poor
connections can often be the cause of a problem in an electrical circuit.
Verify that all connections in the circuit are clean and secure and that all
connections are in good condition. If a problem with the connection is
found, correct the problem and verify that this malfunction or diagnostic
code is active before performing this procedure.
Perform open or short-circuit test at each harness connection to identify
the correct harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Monitoring System Detects Abnormally High Current on Action Lamp Circuit 411
During Lamp Test or Action Lamp Operation.
POSSIBLE CAUSE
Action Lamp LED Shorted.
Dash Wiring Harness Shorted.
Tractor Operator Monitor.
0098-10