TM 5-3805-296-23-2
0098
Table 1. 0324 Action Lamp Diagnostic Codes Continued.
098
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
324-3 Warning Lamp Voltage Above
3. At MSD, check for active
0324-03 Warning Lamp
Normal Becomes Inactive Proceed
diagnostic codes (WP 0008).
Voltage Above Normal
to step 4.
Continued
324-3 Warning Lamp Voltage Above
Normal Remains Active Repeat
troubleshooting from the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. Install instrument panel
(Figure 2, Item 3) with six bolts
(Figure 2, Item 4) on ROPS
(Figure 2, Item 5).
6. Install right vent (Figure 2, Item 7)
with two bolts (Figure 2, Item 6) on
instrument panel
(Figure 2, Item 3).
7. Install left vent (Figure 2, Item 2)
with two bolts (Figure 2, Item 1) on
instrument panel
(Figure 2, Item 3).
8. Install instrument panel cover
(Figure 1, Item 3) with six washers
(Figure 1, Item 2) and bolts
(Figure 1, Item 1) on ROPS
(Figure 1, Item 4).
9. Troubleshooting complete.
0098-5