Figure 2. Instrument Panel and Retaining Hardware.
Table 1. 0324 Action Lamp Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
img
.
TM 5-3805-296-23-2
0098
Table 1. 0324 Action Lamp Diagnostic Codes Continued.
098
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
6. Disconnect connector P-C31 from
0324-03 Warning Lamp
instrument panel. Remove action
Voltage Above Normal
lamp LED from connector P-C31
Continued
(WP 0506) (Figure 3).
Figure 3. Connector P-C22 and Connector P-C31 on Instrument Panel.
0098
7. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor connector.
8. Using digital multimeter
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C18
Proceed to Test Step 2.
terminal 13 (WP 0012, Figure 253)  No Continuity Replace tractor
and all other terminals in
operator monitor (WP 0506).
connector P-C18 (WP 0012,
Proceed to Test Step 2.
Figure 253).
Test Step 2. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
0098-4