TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0271-06 Action Alarm
Current Above Normal
Continued
Figure 6. Instrument Panel and Retaining Hardware.
0097
5. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor connector.
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C1
Proceed to Test Step 5.
terminal 52 (WP 0012, Figure 253)
No Continuity Proceed to step 7.
and all other terminals in
connector P-C1 terminal 52
(WP 0012, Figure 253).
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C18
Proceed to Test Step 5.
terminal 4 (WP 0012, Figure 269)
No Continuity Proceed to step 8.
and all other terminals in
connector P-C18
(WP 0012, Figure 269).
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C18
Proceed to Test Step 5.
terminal 4 (WP 0012, Figure 269)
No Continuity Replace tractor
and ground.
operator monitor (WP 0506).
Proceed to Test Step 5.