TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 8. Verify Malfunction is
0271-05 Action Alarm
Resolved.
Current Below Normal
1. Ensure all harness connectors are
Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
271-5 Action Alarm Current Below
Normal Becomes Inactive Proceed
diagnostic codes (WP 0008).
to step 4.
271-5 Action Alarm Current Below
Normal Remains Active Repeat
troubleshooting from the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install instrument panel
(Figure 4, Item 3) with six bolts
(Figure 4, Item 4) on ROPS
(Figure 4, Item 5).
6. If removed, install right vent
(Figure 4, Item 7) with two bolts
(Figure 4, Item 6) on instrument
panel (Figure 4, Item 3).
7. If removed, install left vent
(Figure 4, Item 2) with two bolts
(Figure 4, Item 1) on instrument
panel (Figure 4, Item 3).
8. If removed, install instrument panel
cover (Figure 3, Item 3) with six
washers (Figure 3, Item 2) and
bolts (Figure 3, Item 1) on ROPS
(Figure 3, Item 4).
9. If removed, install lower and upper
plenum on ROPS (WP 0504).
10. If removed, install right trim panel
(WP 0494).
11. Troubleshooting complete.
0097-11