• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
Figure 6. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  462    463    464    465    466  467  468    469    470    471    472  
img
.
TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 4. Test for Shorted Dash
0271-06 Action Alarm
Wiring Harness.
Current Above Normal
1. Remove six bolts
Continued
(Figure 5, Item 1), washers
(Figure 5, Item 2), and instrument
panel cover (Figure 5, Item 3) from
ROPS (Figure 5, Item 4).
Figure 5. Instrument Panel Cover and Retaining Hardware.
0097
2. Remove two bolts
(Figure 6, Item 1) and left vent
(Figure 6, Item 2) from instrument
panel (Figure 6, Item 3).
3. Remove two bolts
(Figure 6, Item 6) and right vent
(Figure 6, Item 7) from instrument
panel (Figure 6, Item 3).
4. Remove six bolts
(Figure 6, Item 4) from instrument
panel (Figure 6, Item 3) and ROPS
(Figure 6, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
0097-14


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.