Table 1. 0271 Action Alarm Diagnostic Codes Continued.
Table 1. 0324 Action Lamp Diagnostic Codes.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  465    466    467    468    469  470  471    472    473    474    475  
img
. .
16
TM 5-3805-296-23-2
0098
TROUBLESHOOTING PROCEDURES
-
0324 ACTION LAMP DIAGNOSTIC CODES
0
098
INITIAL SETUP
Materials/Parts
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Rag, Wiping (WP 0549, Item 28)
0
(WP 0550, Item 181)
Tag, Marker (WP 0549, Item 38)
0
0
Adapter, Communication
References
(WP 0550, Item 3)
0
0
WP 0012
Multimeter, Digital (WP 0550, Item 107)
0
0
WP 0506
Software Kit (ET)
0
WP 0510
(WP 0550, Item 168)
0
0
Test Set, Electronic (MSD)
WP 0540
0
(WP 0550, Item 175)
0
Equipment Conditions
0
Tip, Needle (WP 0550, Item 178)
0
Machine parked (TM 5-3805-296-10)
0
0
MSD connected (WP 0008)
0
GENERAL
00098
This work package contains field maintenance troubleshooting information for the Military 621G Scraper. Each
malfunction or symptom is followed by the possible cause(s) and suggested remedy or remedies. Use this work
package to help isolate and correct system problems. Ensure all PMCS and operator troubleshooting procedures
(TM 5-3805-296-10) have been performed.