Figure 3. Instrument Panel Cover and Retaining Hardware.
Table 1. 0271 Action Alarm Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  458    459    460    461    462  463  464    465    466    467    468  
img
.
TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
2. Remove two bolts
0271-05 Action Alarm
(Figure 4, Item 1) and left vent
Current Below Normal
(Figure 4, Item 2) from instrument
Continued
panel (Figure 4, Item 3).
3. Remove two bolts
(Figure 4, Item 6) and right vent
(Figure 4, Item 7) from instrument
panel (Figure 4, Item 3).
4. Remove six bolts (Figure 4, Item 4)
from instrument panel
(Figure 4, Item 3) and ROPS
(Figure 4, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
Figure 4. Instrument Panel and Retaining Hardware.
0097
5. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor connector.
6. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Replace tractor operator monitor
between connector P-C1
(WP 0506).
terminal 52 (WP 0012, Figure 253)
Proceed to Test Step 8.
and connector P-C18 terminal 4
Resistance Greater Than 5.0 Ohms
(WP 0012, Figure 269).
Replace dash wiring harness
(WP 0510).
Proceed to Test Step 8.
0097-10