Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
2. Remove two bolts
0271-05 Action Alarm
(Figure 4, Item 1) and left vent
Current Below Normal
(Figure 4, Item 2) from instrument
Continued
panel (Figure 4, Item 3).
3. Remove two bolts
(Figure 4, Item 6) and right vent
(Figure 4, Item 7) from instrument
panel (Figure 4, Item 3).
4. Remove six bolts (Figure 4, Item 4)
from instrument panel
(Figure 4, Item 3) and ROPS
(Figure 4, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
Figure 4. Instrument Panel and Retaining Hardware.
0097
5. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor connector.
(WP 0540), measure resistance
Replace tractor operator monitor
between connector P-C1
(WP 0506).
terminal 52 (WP 0012, Figure 253)
Proceed to Test Step 8.
and connector P-C18 terminal 4
(WP 0012, Figure 269).
Replace dash wiring harness
(WP 0510).
Proceed to Test Step 8.