• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
Figure 3. Instrument Panel Cover and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  456    457    458    459    460  461  462    463    464    465    466  
img
TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes Continued.
097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Test Fuse Panel Wiring
0271-05 Action Alarm
Harness for High Resistance or
Current Below Normal
Open.
Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector CG-C1
(WP 0012, Figure 283) from
connector W-C8
(WP 0012, Figure 282).
3. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 6.
between connector CG-C6
Resistance Greater Than 5.0 Ohms
terminal 1 (WP 0012, Figure 309)
Replace fuse panel wiring harness
and connector CG-C1 terminal 12
(WP 0515).
(WP 0012, Figure 283).
Proceed to Test Step 8.
Test Step 6. Test Main Cab Wiring
Harness for High Resistance or
Open.
1. Remove upper and lower plenum
from ROPS (WP 0504).
2. Disconnect connector P-C1
(WP 0012, Figure 253) from
connector W-C7
(WP 0012, Figure 252).
3. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 7.
between connector W-C8
Resistance Greater Than 5.0 Ohms
terminal 12 (WP 0012, Figure 282)
Replace main cab wiring harness
and connector W-C7 terminal 52
(WP 0505).
(WP 0012, Figure 252).
Proceed to Test Step 8.
0097-8


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.