Table 1. 0324 Action Lamp Diagnostic Codes Continued.
Figure 6. Connector P-C22 and Connector P-C31 on Instrument Panel.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  471    472    473    474    475  476  477    478    479    480    481  
img
.
TM 5-3805-296-23-2
0098
Table 1. 0324 Action Lamp Diagnostic Codes Continued.
098
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove two bolts
0324-05 Warning Lamp
(Figure 5, Item 1) and left vent
Open/Short to Ground
(Figure 5, Item 2) from instrument
Continued
panel (Figure 5, Item 3).
4. Remove two bolts
(Figure 5, Item 6) and right vent
(Figure 5, Item 7) from instrument
panel (Figure 5, Item 3).
5. Remove six bolts (Figure 5, Item 4)
from instrument panel
(Figure 5, Item 3) and ROPS
(Figure 5, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
Figure 5. Instrument Panel and Retaining Hardware.