Table 1. 0600 Hydraulic Oil Temperature Sensor Diagnostic Codes Continued.
Table 1. 0600 Hydraulic Oil Temperature Sensor Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  917    918    919    920    921  922  923    924    925    926    927  
img
. . . . . . . . . .
TM 5-3805-296-23-1
0062
Table 1. 0600 Hydraulic Oil Temperature Sensor Diagnostic Codes Continued.
062
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
4. Using digital multimeter
0600-04 Hydraulic Oil
Continuity Replace chassis wiring
(WP 0540), test for continuity
Temperature Sensor Voltage
harness (WP 0305).
between connector J-C8
Below Normal Continued
Proceed to Test Step 6.
terminal 46 (WP 0012, Figure 100)
No Continuity Proceed to Test
and ground.
Step 5.
Test Step 5. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector W-C12
(WP 0012, Figure 88) from
transmission/chassis ECM.
2. Disconnect connector W-C13
(WP 0012, Figure 89) from
transmission/chassis ECM.
3. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1
Proceed to Test Step 6.
terminal 46 (WP 0012, Figure 99)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C1
(WP 0012, Figure 99).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 6.
terminal 16 (WP 0012, Figure 88)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C12
(WP 0012, Figure 88).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 6.
terminal 16 (WP 0012, Figure 88)
No Continuity Proceed to step 6.
and all terminals in connector
W-C13 (WP 0012, Figure 89).
6. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 6.
terminal 16 (WP 0012, Figure 88)
No Continuity Replace transmission/
and ground.
chassis ECM (WP 0495).
Proceed to Test Step 6.
Test Step 6. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
0062-12