TM 5-3805-296-23-1
0062
Table 1. 0600 Hydraulic Oil Temperature Sensor Diagnostic Codes Continued.
062
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 3. Test for Shorted
0600-04 Hydraulic Oil
Transmission Wiring Harness.
Temperature Sensor Voltage
1. Disconnect connector A-C1
Below Normal Continued
from connector J-C3
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector A-C6
Proceed to Test Step 6.
No Continuity Proceed to step 3.
and all other terminals
in connector A-C6
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector A-C1
Proceed to Test Step 6.
No Continuity Proceed to step 4.
and all other terminals
in connector A-C1
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector A-C1
Proceed to Test Step 6.
No Continuity Proceed to Test
and ground.
Step 4.
Test Step 4. Test for Shorted Chassis
Wiring Harness.
1. Disconnect connector J-C8
from connector W-C1
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C3 terminal 2
Proceed to Test Step 6.
No Continuity Proceed to step 3.
other terminals in connector J-C3
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 6.
No Continuity Proceed to step 4.
and all other terminals
in connector J-C8
0062-11