Table 1. 0444 Start Relay Diagnostic Codes.
Table 1. 0444 Start Relay Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  806    807    808    809    810  811  812    813    814    815    816  
img
. .
TM 5-3805-296-23-1
0058
Table 1. 0444 Start Relay Diagnostic Codes Continued.
058
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Start
0444-03 Starter Motor Relay
Relay.
Voltage Above Normal
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove start relay from fuse
panel (Figure 1).
3. Remove flood enable relay from
fuse panel (Figure 1). Install flood
enable relay on start relay
connector on fuse panel.
Figure 1. Start Relay and Flood Enable Relay.
0058
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
444-3 Starter Motor Relay Voltage
5. At MSD, check for active
Above Normal Becomes Inactive
diagnostic code 444-3 Starter
Replace start relay.
Motor Relay Voltage Above
Proceed to Test Step 4.
Normal (WP 0008).
444-3 Starter Motor Relay Voltage
Above Remains Active Proceed to
Test Step 2.
0058-3