Table 1. 0444 Start Relay Diagnostic Codes Continued.
Figure 3. Start Relay Connector Terminals on Fuse Panel.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  809    810    811    812    813  814  815    816    817    818    819  
img
. .
TM 5-3805-296-23-1
0058
Table 1. 0444 Start Relay Diagnostic Codes Continued.
058
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0444-05 Starter Motor Relay
Test Step 1. Test for Open Start
Current Below Normal
Relay.
Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove start relay from fuse
panel (Figure 2).
3. Remove flood enable relay from
fuse panel (Figure 2). Install flood
enable relay on start relay
connector on fuse panel.
Figure 2. Start Relay and Flood Enable Relay.
0058
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
5. At MSD, check for active
444-5 Starter Motor Relay Current
diagnostic code 444-5 Starter
Below Normal Becomes Inactive
Motor Relay Current Below Normal
Replace start relay.
(WP 0008).
Proceed to Test Step 4.
444-5 Starter Motor Relay Current
Below Normal Remains Active
Proceed to Test Step 2.
0058-6