Table 1. 0358 Pilot Pressure Supply Solenoid Valve Diagnostic Codes Continued.
057
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Open Pilot
0358-05 Implement Pilot
Solenoid.
Pressure Supply Solenoid
1. Turn ignition switch and battery
Valve Current Below Normal
disconnect switch to OFF position
Continued
(TM 5-3805-296-10).
2. Disconnect connector A-C3
pilot solenoid connector
3. Connect jumper wire between
terminal 1 and terminal 2
of connector A-C3
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
5. At MSD, check for active
358-6 Implement Pilot Pressure
diagnostic code 358-5 Implement
Pilot Pressure Supply Solenoid
Above Normal Becomes Active
Valve Current Below Normal
Replace pilot solenoid (WP 0321).
Proceed to Test Step 5.
358-5 Implement Pilot Pressure
Below Normal Remains Active
Proceed to Test Step 2.
Test Step 2. Test Transmission
or Open.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Do not remove jumper wire from
terminal 1 and terminal 2 of
connector A-C3
3. Disconnect connector A-C1
from connector J-C3
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 3.
between connector A-C1
terminal 8 and terminal 38
Replace transmission wiring harness
(WP 0266).
Proceed to Test Step 5.
0057-5