Table 1. 0358 Pilot Pressure Supply Solenoid Valve Diagnostic Codes.
Table 1. 0358 Pilot Pressure Supply Solenoid Valve Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  796    797    798    799    800  801  802    803    804    805    806  
img
. . . . . . . . . . . . . .
TM 5-3805-296-23-1
0057
Table 1. 0358 Pilot Pressure Supply Solenoid Valve Diagnostic Codes Continued.
057
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Shorted Chassis
0358-03 Implement Pilot
Wiring Harness.
Pressure Supply Solenoid
1. Disconnect connector J-C8
Valve Voltage Above Normal
(WP 0012, Figure 100)
Continued
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C3 terminal 8
Proceed to Test Step 4.
(WP 0012, Figure 101) and all
No Continuity Proceed to step 3.
other terminals in connector J-C3
(WP 0012, Figure 101).
3. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 4.
terminal 59 (WP 0012, Figure 100)
No Continuity Proceed to
and all other terminals
Test Step 3.
in connector J-C8
(WP 0012, Figure 100).
Test Step 3. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector W-C13
(WP 0012, Figure 89) from
transmission/chassis ECM.
2. Disconnect connector W-C12
(WP 0012, Figure 88) from
transmission/chassis ECM.
3. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1
Proceed to Test Step 4.
terminal 59 (WP 0012, Figure 99)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C1
(WP 0012, Figure 99).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 58 (WP 0012, Figure 89)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C13
(WP 0012, Figure 89).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
terminal 58 (WP 0012, Figure 89)
No Continuity Replace transmission/
and all terminals in connector
chassis ECM (WP 0495).
W-C12 (WP 0012, Figure 88).
Proceed to Test Step 4.