Table 1. 0262 Five-Volt Sensor Supply Diagnostic Codes Continued.
030
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 4. Verify Malfunction is
0262-03 Five-Volt Sensor DC
Resolved.
Supply Voltage Above
1. Ensure all harness connectors are
Normal Continued
connected.
2. At MSD, check for active
262-3 Five-Volt Sensor DC Supply
Voltage Above Normal Becomes
diagnostic codes (WP 0008).
Inactive Proceed to step 3.
262-3 Five-Volt Sensor DC Supply
Voltage Above Normal Remains
Active Repeat troubleshooting from
the beginning.
3. Install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0030
4. Install left frame access plate
(WP 0376).
5. Troubleshooting complete.