Table 1. 0262 Five-Volt Sensor Supply Diagnostic Codes.
Table 1. 0262 Five-Volt Sensor Supply Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  577    578    579    580    581  582  583    584    585    586    587  
img
. . . .
TM 5-3805-296-23-1
0030
Table 1. 0262 Five-Volt Sensor Supply Diagnostic Codes Continued.
030
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Engine
0262-03 Five-Volt Sensor DC
Interface Wiring Harness or Fuel
Supply Voltage Above
Filter Wiring Harness.
Normal Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove four bolts
(Figure 1, Item 1), washers
(Figure 1, Item 2), bushings
(Figure 1, Item 3), and splash
shield (Figure 1, Item 4) from
machine.
Figure 1. Splash Shield and Retaining Hardware.
0030
3. Disconnect connector CL-C10
(WP 0012, Figure 32)
from connector CM-C11
(WP 0012, Figure 31).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
262-3 Five-Volt Sensor DC Supply
5. At MSD, check for active
Voltage Above Normal Remains
diagnostic code 262-3 Five-Volt
Active Proceed to Test Step 2.
Sensor DC Supply Voltage Above
262-3 Five-Volt Sensor DC Supply
Normal (WP 0008).
Voltage Above Normal Becomes
Inactive Proceed to Test Step 3.
0030-3


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.