TM 5-3805-296-23-1
0019
Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.
019
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0041-03 8 Volt DC Supply
Continuity Replace engine interface
(WP 0540), test for continuity
Voltage Above Normal
wiring harness (WP 0211) and basic
between connector CL-C1
Continued
engine wiring harness (WP 0251).
Proceed to Test Step 3.
and all terminals in connector CM-
No Continuity Replace engine ECM
(WP 0252).
Proceed to Test Step 3.
Test Step 3. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. If removed, install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0019
3. Install left frame access plate
(WP 0376).
4. At MSD, check for active
41-3 8 Volt DC Supply Voltage Above
Normal Becomes Inactive
Troubleshooting complete.
41-3 8 Volt DC Supply Above Normal
Remains Active Repeat
troubleshooting from the beginning.