Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.
Figure 4. Splash Shield and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  473    474    475    476    477  478  479    480    481    482    483  
img
. . . . . . . . .
TM 5-3805-296-23-1
0019
Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.
019
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
2. Disconnect connector CM-C1
0041-04 8 Volt DC Supply
(WP 0012, Figure 30) from engine
Voltage Below Normal
ECM.
Continued
3. Disconnect connector CL-C1
(WP 0012, Figure 45) from engine
ECM.
4. Using digital multimeter
Continuity Replace engine interface
(WP 0540), test for continuity
wiring harness (WP 0211).
between connector CL-C3
Proceed to Test Step 4.
terminal 28 (WP 0012, Figure 86)
No Continuity Proceed to step 5.
and all other terminals
in connector CL-C3
(WP 0012, Figure 86).
5. Using digital multimeter
Continuity Replace engine interface
(WP 0540), test for continuity
wiring harness (WP 0211).
between connector CL-C1
Proceed to Test Step 4.
terminal 4 (WP 0012, Figure 45)
No Continuity Proceed to step 6.
and all other terminals
in connector CL-C1
(WP 0012, Figure 45).
6. Using digital multimeter
Continuity Replace engine interface
(WP 0540), test for continuity
wiring harness (WP 0211) and basic
between connector CL-C1
engine wiring harness (WP 0251).
terminal 4 (WP 0012, Figure 45)
Proceed to Test Step 4.
and all terminals in connector CM-
No Continuity Proceed to step 7.
C1 (WP 0012, Figure 30).
7. Using digital multimeter
Continuity Replace engine interface
(WP 0540), test for continuity
wiring harness (WP 0211).
between connector CL-C1
Proceed to Test Step 4.
terminal 4 (WP 0012, Figure 45)
No Continuity Replace engine ECM
and ground.
(WP 0252).
Proceed to Test Step 4.