COOLING SYSTEM SERVICE - Continued
LOWER COOLANT TANK REPLACEMENT

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  506    507    508    509    510  511  512    513    514    515    516  
img
.
TM 5-3805-296-23-4
0256
COOLANT LEVEL CHECK CONTINUED
2. If it is necessary to add coolant, slowly loosen cooling system cap (Figure 5, Item 2) to relieve system
pressure. Remove cooling system cap (Figure 5, Item 2).
3. Fill cooling system to bottom of filler tube (Figure 5, Item 3). Adding coolant above bottom of filler tube will
cause coolant to overflow cooling system.
4. Maintain coolant level between top of sight glass (Figure 5, Item 4) and bottom of filler tube (Figure 5, Item 3).
5. Inspect cooling system cap seal for debris, foreign material, or damage. Clean radiator filler cap with a clean
cloth. Replace cooling system cap if damaged.
6. Install cooling system cap on upper coolant tank (Figure 5, Item 1).
Figure 5. Cooling System Check.
0256
END OF TASK
FOLLOW-ON TASKS
000256
1. Close front hood (TM 5-3805-296-10).
2. Close right engine door (TM 5-3805-296-10).
3. Verify correct operation of machine (TM 5-3805-296-10).
END OF TASK
END OF WORK PACKAGE