TM 5-3805-296-23-4
0257
INSTALLATION
000257
1. Install weatherstrip (Figure 3, Item 3) on lower coolant tank (Figure 3, Item 1).
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
2. Apply pipe sealant on fitting (Figure 3, Item 2).
3. Install fitting (Figure 3, Item 2) on lower coolant tank (Figure 3, Item 1).
Figure 3. Lower Coolant Tank and Weatherstrip.
0257
WARNING
Lower coolant tank will fall when bolts are removed. Use assistance to adequately support
lower coolant tank before installing bolts. Failure to follow this warning may result in injury
to personnel.
NOTE
Lower coolant tank weighs approximately 25 lb (11 kg).