TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does Not
Operate in One or More
Speeds Continued
Figure 3. Plate and Retaining Hardware.
0134
2. Disconnect connector H-C3
(WP 0012, Figure 250) from fan
speed switch (WP 0012,
Figure 249).
3. Reset blower circuit breaker
(TM 5-3805-296-10).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10). Wait 30
seconds before proceeding to next
step.
5. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
6. Inspect blower circuit breaker in
Circuit Breaker Not Tripped
circuit breaker panel
Replace fan speed switch (WP 0467).
(TM 5-3805-296-10).
Proceed to Test Step 38.
Circuit Breaker Tripped DO NOT
Reset blower circuit breaker.
Proceed to Test Step 14.
Test Step 14. Test for Shorted
Headliner Wiring Harness.
1. Disconnect connector W-C2
(WP 0012, Figure 224) from
connector H-C7 (WP 0012,
Figure 225).