TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does Not
Continuity Replace headliner wiring
(WP 0540), test for continuity
Operate in One or More
harness (WP 0497).
between connector H-C7
Speeds Continued
Reset blower circuit breaker
terminal 16 (WP 0012, Figure 225)
(TM 5-3805-296-10).
and all other terminals in
Proceed to Test Step 38.
connector H-C7 (WP 0012,
No Continuity Proceed to step 3.
Figure 225).
Continuity Replace headliner wiring
(WP 0540), test for continuity
harness (WP 0497).
between connector H-C7
Reset blower circuit breaker
terminal 16 (WP 0012, Figure 225)
(TM 5-3805-296-10).
and ground.
Proceed to Test Step 38.
No Continuity Proceed to Test
Step 15.
Test Step 15. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector CG-C1
(WP 0012, Figure 283) from
connector W-C8
(WP 0012, Figure 282).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C2
Reset blower circuit breaker
terminal 16 (WP 0012, Figure 224)
(TM 5-3805-296-10).
and all other terminals in
Proceed to Test Step 38.
connector W-C2
No Continuity Proceed to step 3.
(WP 0012, Figure 224).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C2
Reset blower circuit breaker
terminal 16 (WP 0012, Figure 224)
(TM 5-3805-296-10).
and ground.
Proceed to Test Step 38.
No Continuity Proceed to step 4.
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C8
Reset blower circuit breaker
terminal 6 (WP 0012, Figure 282)
(TM 5-3805-296-10).
and all other terminals in
Proceed to Test Step 38.
connector W-C8 (WP 0012,
No Continuity Proceed to Test
Figure 282).
Step 16.
0134-10