TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does Not
Continuity Replace headliner wiring
(WP 0540), test for continuity as
Operate in One or More
harness (WP 0497).
follows:
Speeds Continued
Reset blower circuit breaker
a. Between connector H-C7
(TM 5-3805-296-10).
terminal 3 (WP 0012,
Proceed to Test Step 38.
Figure 225) and all other
No Continuity Proceed to step 6.
terminals in connector
H-C7 (WP 0012, Figure 225).
b. Between connector H-C7
terminal 3 (WP 0012,
Figure 225) and ground.
c.
Between connector H-C7
terminal 5 (WP 0012,
Figure 225) and all other
terminals in connector
H-C7 (WP 0012, Figure 225).
d. Between connector H-C7
terminal 5 (WP 0012,
Figure 225) and ground.
e. Between connector H-C7
terminal 12 (WP 0012,
Figure 225) and all other
terminals in connector
H-C7 (WP 0012, Figure 225).
f.
Between connector H-C7
terminal 12 (WP 0012,
Figure 225) and ground.
g. Between connector H-C7
terminal 14 (WP 0012,
Figure 225) and all other
terminals in connector
H-C7 (WP 0012, Figure 225).
h. Between connector H-C7
terminal 14 (WP 0012,
Figure 225) and ground.
0134-13