• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
Figure 6. Top Plate.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  856    857    858    859    860  861  862    863    864    865    866  
img
.
TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Circuit Breaker Not Tripped
7. Inspect blower circuit breaker in
Blower Motor Does Not
Proceed to Test Step 21.
circuit breaker panel
Operate in One or More
Circuit Breaker Tripped Replace
(TM 5-3805-296-10).
Speeds Continued
heat A/C switch (WP 0470).
Reset blower circuit breaker
(TM 5-3805-296-10).
Proceed to Test Step 38.
Test Step 21. Test for Shorted Air
Conditioner Wiring Harness.
1. Remove HVAC access cover
(WP 0479).
2. Loosen wingnut (Figure 5, Item 5)
and remove plate (Figure 5,
Item 6) and filter (Figure 5, Item 7)
from HVAC assembly (Figure 5,
Item 4).
3. Remove four bolts
(Figure 5, Item 1) and washers
(Figure 5, Item 2) from HVAC
assembly (Figure 5, Item 4).
4. Remove bolt (Figure 5, Item 8),
washer (Figure 5, Item 9) and
bracket (Figure 5, Item 10) from
front plate (Figure 5, Item 3) and
HVAC assembly. (Figure 5,
Item 4).
Figure 5. Front Plate.
0134
0134-17


Privacy Statement