Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 16. Test for Shorted Fuse
Blower Motor Does Not
Panel Wiring Harness.
Operate in One or More
Speeds Continued
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515).
between connector CG-C1
Reset blower circuit breaker
terminal 6 (WP 0012, Figure 283)
(TM 5-3805-296-10).
and all other terminals in
Proceed to Test Step 38.
connector CG-C1 (WP 0012,
No Continuity Proceed to step 2.
Figure 283).
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515).
between connector CG-C1
Reset blower circuit breaker
terminal 6 (WP 0012, Figure 283)
(TM 5-3805-296-10).
and ground.
Proceed to Test Step 38.
No Continuity Replace blower motor
breaker and wiring assembly
(WP 0496).
Proceed to Test Step 38.