TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Turn fan speed switch to
Blower Motor Does Not
position O (TM 5-3805-296-10).
Operate in One or More
Speeds Continued
8. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
Circuit Breaker Not Tripped
9. Inspect blower circuit breaker in
Proceed to step 10.
circuit breaker panel
Circuit Breaker Tripped Proceed to
(TM 5-3805-296-10).
Test Step 17.
10. Turn battery disconnect switch to
ON position and start engine
(TM 5-3805-296-10).
11. Set heat AC switch to A/C position
(TM 5-3805-296-10).
12. Turn fan speed switch to
position IIII (TM 5-3805-296-10).
13. Turn fan speed switch to
position O (TM 5-3805-296-10).
14. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
Circuit Breaker Not Tripped
15. Inspect blower circuit breaker in
Proceed to Test Step 38.
circuit breaker panel
Circuit Breaker Tripped Proceed to
(TM 5-3805-296-10).
Test Step 23.
Test Step 13. Test for Shorted Fan
Speed Switch.
1. Remove four bolts (Figure 3,
Item 2) and plate (Figure 3, Item 1)
from headliner (Figure 3, Item 3).
0134-8