TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does Not
Operate in One or More
Speeds Continued
Figure 2. Blower Breaker and Wiring.
0134
Test Step 12. Test Reset Blower
Circuit Breaker.
1. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10). Wait 30
seconds before proceeding to next
step.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
3. Inspect blower circuit breaker in
Circuit Breaker Not Tripped
circuit breaker panel
Proceed to step 4.
(TM 5-3805-296-10).
Circuit Breaker Tripped Proceed to
Test Step 13.
4. Set heat AC switch to heat position
(TM 5-3805-296-10).
5. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
6. Turn fan speed switch to position I,
II, III, and IIII (TM 5-3805-296-10).