TM 5-3805-296-23-2
0122
Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
2. On MSD, select Status Group #12
Function Will Not Operate or
(Figure 8, Item 1).
Fails To Turn Off
3. While monitoring Ejector Cylinder
Status Changes Accordingly
Automatically Continued
Head End Pressure Switch status
Proceed to Test Step 15.
(Figure 8, Item 2), move and hold
Status Fails to Change Accordingly
joystick in ejector automatic
Inspect hose between ejector kickout
reverse position
switch and rear main control valve for
(TM 5-3805-296-10). Hold joystick
anything that would restrict hydraulic
in this position for two seconds
fluid pressure to switch, and replace as
after ejector reaches end of travel
necessary. If hose is not restricted,
and then release joystick. Switch
replace ejector kickout switch
status should change from closed
(WP 0350).
to open and back to closed.
Proceed to Test Step 15.
Figure 8. Selecting Status Group #12.
0122
Test Step 15. Verify Malfunction is
Resolved.
Operate ejector automatic return
Malfunction No Longer Present
function (TM 5-3805-296-10).
Troubleshooting complete.
Malfunction is Active Repeat
troubleshooting from the beginning.
END OF WORK PACKAGE