Table 1. All Implements Fail To Operate, Cushion Hitch Operates Normally Continued.
0123
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. On MSD, select Status Group #11
All Implements Fail To
(Figure 3, Item 1) and view
Operate, Cushion Hitch
Hydraulic Oil Temperature
Operates Normally
(Figure 3, Item 2). Allow hydraulic
Continued
oil to warm up to 145F to 155F
(63C to 68C) before proceeding
to next step.
Figure 3. Status Group #11.