Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off Automatically - Continued.
Figure 7. Accessing Status Menu.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  763    764    765    766    767  768  769    770    771    772    773  
img
TM 5-3805-296-23-2
0122
Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
3. Using digital multimeter
Continuity Replace main cab wiring
Function Will Not Operate or
(WP 0540), test for continuity
harness (WP 0505).
Fails To Turn Off
between connector W-C3
Proceed to Test Step 15.
Automatically Continued
terminal 11 (WP 0012, Figure 139)
No Continuity Proceed to step 4.
and all other terminals in
connector W-C3 (WP 0012,
Figure 139).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 15.
terminal 17 (WP 0012, Figure 88)
No Continuity Proceed to step 5.
and all other terminals in
connector W-C12
(WP 0012, Figure 88).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 15.
terminal 17 (WP 0012, Figure 88)
No Continuity Proceed to step 6.
and all terminals in connector
W-C13 (WP 0012, Figure 89).
6. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 15.
terminal 17 (WP 0012, Figure 89)
No Continuity Replace transmission/
and ground.
chassis ECM (WP 0495).
Proceed to Test Step 15.
Test Step 13. Perform Calibration.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Connect connector F-C7
(WP 0012, Figure 160) to ejector
kickout switch connector
(WP 0012, Figure 159).
3. Perform ejector lever sensor
Calibration Successful Proceed to
calibration (WP 0173).
step 4.
Calibration Unsuccessful, Fault
Code Active Diagnose and repair
fault code displayed on screen
(WP 0005).
Proceed to Test Step 15.
0122-12