TM 5-3805-296-23-2
0122
Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
Resistance 5.0 Ohms or Less
Function Will Not Operate or
(WP 0540), measure resistance
Proceed to Test Step 5.
Fails To Turn Off
between connector F-C8
Automatically Continued
terminal 11 and terminal 12
Replace implement wiring harness
(WP 0012, Figure 146).
(WP 0349).
Proceed to Test Step 15.
Test Step 5. Test Draft Frame and
Bowl Side Wiring Harness for High
Resistance or Open.
1. Remove jumper wire from
terminal A and terminal C of
connector F-C7 (WP 0012,
Figure 160).
2. Connect jumper wire between
terminal 11 and terminal 12 of
connector AE-C5
(WP 0012, Figure 145).
3. Disconnect connector AE-C1
(WP 0012, Figure 144) from
connector E-C2
(WP 0012, Figure 143).
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 6.
between connector AE-C1
terminal 11 and terminal 12
Replace draft frame and bowl side
(WP 0012, Figure 144).
wiring harness (WP 0348).
Proceed to Test Step 15.
Test Step 6. Test Hitch Wiring
Harness for High Resistance or
Open.
1. Lower left frame access plate
(WP 0376).
2. Remove jumper wire from terminal
11 and terminal 12 of connector
AE-C5 (WP 0012, Figure 145).
3. Connect jumper wire between
terminal 11 and terminal 12 of
connector E-C2
(WP 0012, Figure 143).
4. Disconnect connector E-C1
(WP 0012, Figure 140) from
connector W-C3
(WP 0012, Figure 139).
0122-7