TM 5-3805-296-23-2
0122
Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
6. On MSD, select Status Group #12
Status Displays Open Proceed to
Function Will Not Operate or
(Figure 4, Item 1) and view Ejector
Test Step 4.
Fails To Turn Off
Cylinder Head End Pressure
Status Displays Closed Replace
Automatically Continued
Switch status (Figure 4, Item 2).
ejector kickout switch (WP 0350).
Proceed to Test Step 15.
Figure 4. Selecting Status Group #12.
0122
Test Step 4. Test Implement Wiring
Open.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Do not remove jumper wire from
terminal A and terminal C of
connector F-C7
(WP 0012, Figure 160).
3. Disconnect connector F-C8
(WP 0012, Figure 146) from
connector AE-C5
(WP 0012, Figure 145).