Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off Automatically.
Figure 2. Selecting Status Group #12.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  754    755    756    757    758  759  760    761    762    763    764  
img
.
TM 5-3805-296-23-2
0122
Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
Test Step 1. Verify Malfunction is
Function Will Not Operate or
Active.
Fails To Turn Off
Perform Implement, Cushion Hitch,
Cause of Malfunction Identified and
Automatically Continued
and Steering System Operation Test
Repaired During Testing
(WP 0172).
Troubleshooting complete.
Cause of Malfunction Not Identified
During Testing, Malfunction Active
Proceed to Test Step 2.
Test Step 2. Test Ejector Kickout
Switch Status.
1. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
2. On MSD, select Information
(Figure 1, Item 1) and Status
(Figure 1, Item 2).