Table 1. Automatic Ejector Return Function Will Not Operate or Fails To Turn Off
Automatically - Continued.
0122
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Automatic Ejector Return
3. On MSD, select Status Group #12
Status Displays Open Proceed to
Function Will Not Operate or
(Figure 2, Item 1) and view Ejector
Test Step 3.
Fails To Turn Off
Cylinder Head End Pressure
Status Displays Closed Proceed to
Automatically Continued
Switch status (Figure 2, Item 2).
Test Step 8.
Figure 2. Selecting Status Group #12.
0122
Test Step 3. Test for Open Ejector
Kickout Switch.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector F-C7
(WP 0012, Figure 160) from
ejector kickout switch connector
(WP 0012, Figure 159).
3. Connect jumper wire between
terminal A and terminal C of
connector F-C7 (WP 0012,
Figure 160).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).